Which radio approvels has your M2M device to pass? EA#

The table with radio approvals is not complete.

Testing for world region

Reference

Type of testing

Specifiaction

Notes

Europe

R&TTE Directive Article 3.2

Mobile Communication – Radiated Spurious Emission 2G

EN 301 511

POS terminal, People tracker, Electricity meter

Europe

R&TTE Directive Article 3.2

Radio – Radio test EN 300 220 – Transceiver (Tx, Rx class 3)

EN 300 220

Electricity meter (ISM 868 MHz)

Europe

R&TTE Directive Article 3.1(b)

EMC – R&TTE acc. EN 301 489-7 (GSM) – AC/DC powered

EN 301 489-7

POS terminal, People tracker, Electricity meter

Europe

R&TTE Directive Article 3.1(b)

EMC – R&TTE acc. EN 301 489-3 (SRD) – add on testing

EN 301 489-3

Electricity meter (ISM 868 MHz)

Europe

R&TTE Directive Article 3.1(a)

Electrical safety test EN 60950-1, main powered device

EN 60950-1

POS terminal, People tracker, Electricity meter

Europe

R&TTE Directive Article 3.1(a)

Radio – SAR test – body position

EN 62311

POS terminal, People tracker (GSM/GPRS 900/1800)

Europe

European Union – R&TTE Notified Body Service – Annex IV Assessment – Licenced Device

POS terminal, People tracker, Electricity meter

USA/Europe

Mobile Communication – RF exposure calculation based on radio test results

CFR Part 47, EU recommendation 199/519/EEC

USA

Mobile Communication – Radiated Spurious Emission 2G

NAPRD

POS terminal, People tracker, Electricity meter

USA

Mobile Communication – SIM/USIM Electrical conformance testing

NAPRD

POS terminal, People tracker, Electricity meter

USA

EMC – FCC/Canada conducted and radiated up to 5GHz

CISPR 22, FCC part 15B

POS terminal, People tracker, Electricity meter

USA

Radio – SAR test FCC – body position

FCC OET Bulletin 65 Supplement C

POS terminal, People tracker (GSM/GPRS 900/1800)

USA

Radio – Radio test FCC part 15.249. Inclusive test report.

47 CFR Part 15

Electricity meter (ISM 915 MHz)

USA

United States – Statemens of DoC (Declaration of Conformity)

Electricity meter (without ISM Band)

USA

United States – TCB Approval Service – Licensed Device – Part 22/24/90/95

POS terminal, People tracker (own FCC-ID)

USA

United States – TCB Approval Service – Confidentiality fee

POS terminal, People tracker (own FCC-ID)

USA

Mobile Communication – PTCRB certification handling

POS terminal, People tracker, Electricity meter

USA

Radio – Over the air test TRP / 1 band, 1 channel

CTIA OTA Performance

3D

USA

Radio – Over the air test TIS / 1 band, 1 channel

CTIA OTA Performance

3D

Please take care that in the EU we do not have an Over the Air test like TRP and TIS. TRP and TIS are not a part of R&TTE. If you would like to make direct business with big Cellular Providers then some of them in the EU will ask for TRP and TSI as well. You product may have R&TTE but TRP or TSI is too bad to get listed with the Cellular Provider. If you are not sure which approvals and tests your M2M device has to pass it is hight recommended to contact a third party with skills in radio approvals and Cellular Provider tests.

Updated: 2013-07-23 — 5:29 PM

1 Comment

Add a Comment
  1. Hi Harald
    You changed TSI=>TIS at two locations. But there is still one TSI:
    “You product may have R&TTE but TRP or TSI is too worst to get listed with the Cellular Provider.”
    You might also correct from “worst” to “bad”.